Abstract
The supercapacitor thermal management system is of great significance to the safe operation and aging moni-toring of the supercapacitor. This article provides a solu-tion for estimating the internal temperature through the surface temperature, instead of directly measurement. By adopting a suitable electrothermal coupling model of supercapacitor, the internal temperature can be estimat-ed online via an H-infinity filter. Besides, in order to re-duce error caused by model inaccuracy and noise chang-ing, this paper uses the neural network to correct the result of the H-infinite filter. To verify the effectiveness method proposed in this paper, a series of experiments are designed and conducted. The results shows that the H-∞-ANN joint filter has less error than H-∞ filter alone.
Keywords Temperature observation, Supercapacitor, Online implementation
Copyright ©
Energy Proceedings